@@ -1,9 +1,52 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
    <startup>
        <supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.7.2"/>
    </startup>
  <configSections>
    <!-- For more information on Entity Framework configuration, visit http://go.microsoft.com/fwlink/?LinkID=237468 -->
    <section name="entityFramework" type="System.Data.Entity.Internal.ConfigFile.EntityFrameworkSection, EntityFramework, Version=6.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" requirePermission="false" />
  </configSections>
  <appSettings>
    <add key="OP80QualityData_Test" value="X:\CA4GC20TD_Test\"/>
    <add key="OP60QualityData_Test" value="Q:\Measuring_Data_df_Test\"/>
    <add key="OP60QualityData_Zhengshi" value="Q:\Measuring_Data_dfq\"/>
    <add key="OP60QualityData_Test_Localhost" value="D:\数瀛信息科技\公司项目\DF22001-一汽连杆项目\映射盘文件\OP60(尼伯丁)\"/>
    <!--net use x: \\192.168.216.133\Destination /savecred /persistent:yes
    net use z: \\192.168.216.130\kistler /savecred /persistent:yes
    net use y: \\192.168.216.6\data /savecred /persistent:yes
    net use u: \\192.168.216.130\NutrunnerData /savecred /persistent:yes-->
    <!-- 判断工序是否跳序的基准配置 -->
    <add key="WorkingProcedureAllStr" value="OP05OP10OP20OP30OP35OP40OP50OP60OP70OP80" />
    <add key="WorkPeiceIDPath" value="Y:\qualified" />
    <!-- op30工序的工位质量信息 -->
    <add key="OP30QualityDataFor36Station" value="Z:\" />
    <add key="OP30QualityDataFor45Station" value="U:\" />
    <add key="OP60QualityData" value="V:\" />
    <add key="OP20QualityData" value="W:\" />
    <add key="OP80QualityData" value="X:\CA4GC20TD\" />
    <!--<add key="WorkPeiceIDPath" value="C:\Users\13650\Desktop\yiqi" />-->
    <add key="HeartBeatAlertInterval" value="2000" />
  </appSettings>
</configuration>
  <startup>
    <supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.7.2" />
  </startup>
  <entityFramework>
    <providers>
      <provider invariantName="System.Data.SqlClient" type="System.Data.Entity.SqlServer.SqlProviderServices, EntityFramework.SqlServer" />
    </providers>
  </entityFramework>
  <connectionStrings>
    <!--<add name="SCADA_DF22001_CORE" connectionString="Server=.;Database=iWare.SCADA;User=sa;Password=123abc.com;MultipleActiveResultSets=True" providerName="System.Data.SqlClient" />-->
    <!--<add name="SCADA_DF22001_CORE" connectionString="Server=10.10.40.166;Database=iWare.SCADA;User=sa;Password=123abc.com;MultipleActiveResultSets=True" providerName="System.Data.SqlClient" />-->
    <add name="SCADA_DF22001_CORE" connectionString="Server=192.168.216.203;Database=iWare.SCADA;User=sa;Password=123abc.com;MultipleActiveResultSets=True" providerName="System.Data.SqlClient" />
    <add name="SCModel" connectionString="data source=.;initial catalog=SCTest_new;integrated security=True;MultipleActiveResultSets=True;App=EntityFramework" providerName="System.Data.SqlClient" />
  </connectionStrings>
  <runtime>
    <assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1">
      <dependentAssembly>
        <assemblyIdentity name="Newtonsoft.Json" publicKeyToken="30ad4fe6b2a6aeed" culture="neutral" />
        <bindingRedirect oldVersion="0.0.0.0-10.0.0.0" newVersion="10.0.0.0" />
      </dependentAssembly>
    </assemblyBinding>
  </runtime>