using iWare_SCADA_BusinessLogical.BLL;
|
using iWare_SCADA_BusinessLogical.Utils;
|
using iWare_SCADA_Model;
|
using System;
|
using System.Collections.Generic;
|
using System.Linq;
|
using System.Text;
|
using System.Threading;
|
using System.Threading.Tasks;
|
|
namespace iWare_SCADA_BusinessLogical
|
{
|
/// <summary>
|
/// OP30 心跳监控
|
/// </summary>
|
public class DataCaptureHandler_OP3006: DataCaptureHandler
|
{
|
public static readonly DataCaptureHandler_OP3006 Instance = new DataCaptureHandler_OP3006();
|
|
public DataCaptureHandler_OP3006()
|
{
|
}
|
|
public override string WorkingProcedure
|
{
|
get { return _dataCaptureConfig.WorkingProcedure; }
|
}
|
|
public override string DataCapturePointCode
|
{
|
get { return _dataCaptureConfig.DataCapturePointCode; }
|
}
|
public override string DataCapturePointCname
|
{
|
get { return _dataCaptureConfig.DataCapturePointCname; }
|
}
|
|
|
public override void RefreshDataList(List<DataCaptureConfig> dataCaptureConfig)
|
{
|
}
|
|
public override void DataCaptureStart()
|
{
|
if (SystemValue.isStartedModel)
|
{
|
return;
|
}
|
if (IsCaptureflag)
|
{
|
var plcService = PLCManger.GetSinglePLCService(_dataCaptureConfig);
|
if (plcService == null)
|
{
|
SystemValue.lbl_Alert_OP3006 = $"{RandomHelper.GenerateRandomCode(4)} 没有找到{_dataCaptureConfig.WorkingProcedure}的PLC设备";
|
return;
|
}
|
if (plcService != null && !plcService.IsConnected)
|
{
|
plcService.Close();
|
plcService.OpenService();
|
}
|
DateTime PLCHeartBeatMonitorTime = DateTime.Now;
|
while (true)
|
{
|
try
|
{
|
//_dataCaptureConfig
|
if (plcService == null || !plcService.IsConnected)
|
{
|
SystemValue.lbl_Alert_OP3006 = $" {RandomHelper.GenerateRandomCode(4)} {_dataCaptureConfig.WorkingProcedure} PLC连接已断开,正在尝试打开!";
|
plcService.Close();
|
plcService.OpenService();
|
Thread.Sleep(100);
|
continue;
|
}
|
else
|
{
|
var value = plcService.ReadValuePoint(_dataCaptureConfig.DbNumber, _dataCaptureConfig.Offset, PLCManger.GetTypeForString(_dataCaptureConfig.DataCaptureColumnType));
|
if (!SystemValue.value_OP3006.Equals(value.ToString()))
|
{//心跳监控
|
PLCHeartBeatMonitorTime = DateTime.Now;
|
}
|
if((DateTime.Now- PLCHeartBeatMonitorTime).TotalSeconds> heartBeatAlertInterval)
|
{
|
SystemValue.lbl_Alert_OP3006 = $" {RandomHelper.GenerateRandomCode(4)} {_dataCaptureConfig.WorkingProcedure} PLC连接心跳异常!";
|
}
|
SystemValue.value_OP3006 = value.ToString();
|
|
//写入心跳
|
|
|
|
}
|
SystemValue.lbl_Alert_OP3006 = $"abcdefg:{RandomHelper.GenerateRandomCode(4)}";
|
|
if (!_dataCaptureConfig.DataCaptureFrequency.HasValue || _dataCaptureConfig.DataCaptureFrequency < 10)
|
{
|
Thread.Sleep(5000);
|
}
|
else
|
{
|
Thread.Sleep(_dataCaptureConfig.DataCaptureFrequency.Value);
|
}
|
|
}
|
catch (System.Data.Entity.Validation.DbEntityValidationException ex)
|
{
|
SystemValue.lbl_Alert_OP3006 = $" {RandomHelper.GenerateRandomCode(4)} 读取{WorkingProcedure}工序监控打码标记 出现异常,请查看日志!";
|
Log4NetHelper.WriteErrorLog(PLCManger.GetLogTypeForWorkingProcedure(WorkingProcedure), "读取 {WorkingProcedure}工序监控打码标记数据时异常:", ex);
|
}
|
catch (Exception ex)
|
{
|
SystemValue.lbl_Alert_OP3006 = $" {RandomHelper.GenerateRandomCode(4)} 读取{WorkingProcedure}工序监控打码标记 出现异常,请查看日志!";
|
Log4NetHelper.WriteErrorLog(PLCManger.GetLogTypeForWorkingProcedure(WorkingProcedure), "读取 {WorkingProcedure}工序监控打码标记数据时异常:", ex);
|
}
|
}
|
}
|
else
|
{
|
SystemValue.lbl_Alert_OP3006 = $" {RandomHelper.GenerateRandomCode(4)} {WorkingProcedure}工序监控打码标记 不做校验,请确认配置信息!";
|
Log4NetHelper.WriteInfoLog(PLCManger.GetLogTypeForWorkingProcedure(WorkingProcedure), "读{WorkingProcedure}工序监控打码标记 不做校验,请确认是否配置异常");
|
}
|
}
|
|
}
|
}
|